Blind and Buried Vias: PCB Via Types, Rules and Cost
Blind and buried vias explained: PCB via types, microvias, via in pad, design rules, sequential lamination cost, and when through hole is enough.
Blind and buried vias explained: PCB via types, microvias, via in pad, design rules, sequential lamination cost, and when through hole is enough.

Short answer: Blind and buried vias are PCB vias that do not pass through the whole board. A blind via connects an outer layer to one or more inner layers. A buried via connects inner layers only and cannot be seen from either surface. They free routing space under fine pitch BGAs and shorten high speed paths, but they add drilling and lamination cycles, so use them only when through hole vias and smarter placement can no longer close the design.

Most boards use one via type: the plated through hole via, drilled after all layers are pressed together. As density rises, designers reach for other via types. Knowing the common types of vias makes the stackup conversation with your fabricator much faster.
| Via type | Connects | How it is made | Typical use |
|---|---|---|---|
| Through hole via | Top to bottom | Mechanical drill after final lamination | Default for most boards |
| Blind via | Outer layer to inner layer | Laser or controlled depth drill | BGA breakout, short high speed transitions |
| Buried via | Inner layer to inner layer | Drilled in a sub-stack before final lamination | Freeing outer layer space in dense designs |
| Microvia | Adjacent layers, about 0.15 mm or smaller | Laser drilled, one dielectric layer deep | HDI PCB, fine pitch BGA escape |
| Via in pad | Pad to inner layers | Via filled and plated over (VIPPO) | 0.5 mm pitch BGAs, thermal pads |
A through hole via is cheap and robust, but it occupies every layer it passes, including layers where you wanted routing channels. That is the core reason blind and buried vias exist.
A blind via starts on the top or bottom layer and stops on an inner layer. On a blind via PCB, you can see the opening on one surface only. Short blind vias, one dielectric deep, are usually laser drilled microvias. Deeper blind vias can be mechanically drilled with controlled depth, or built by drilling a sub-stack before lamination.
Blind vias are valuable under fine pitch BGAs. The outer ring of balls escapes on the surface, and the inner rows drop through blind microvias to layer 2 or 3 without blocking routing on the layers below. They also shorten the path for fast signals because there is no unused barrel below the target layer.
A buried via connects two or more inner layers and never reaches either surface. The fabricator drills and plates it in an inner sub-stack, then laminates outer layers over it. Because of that extra pressing step, buried vias are one of the clearest cost drivers in a stackup.
Use buried vias when inner layer routing needs layer changes but the outer layers must stay clear for components, BGA escape or ground stitching. In a 10 to 12 layer design with several high speed buses, buried vias between inner signal layers can avoid a two layer count increase.
The blind via vs buried via question is mostly about where the connection must land and what it costs to build:
Microvias are small laser drilled holes that span one dielectric layer, with an aspect ratio usually kept at or below about 0.75:1 to 1:1 so plating fills reliably. They are the building block of an HDI PCB. Two arrangements matter:
Via in pad puts the via directly inside a component pad. It must be filled and plated over (often called VIPPO), otherwise solder wicks down the hole and leaves voids. Via in pad is common under 0.5 mm pitch BGAs and under exposed thermal pads, where it works together with thermal vias.

Sequential lamination means the board is pressed, drilled and plated more than once. Each cycle adds time, material, registration risk and yield loss. Fabricators often describe HDI builds with notation such as 1+N+1 (one microvia layer on each side of a core stack) or 2+N+2 (two). Every step up in that notation adds roughly one more press cycle.
A practical cost ladder, from cheapest to most expensive:
Ask for a quote at two levels before you commit. The jump from step 3 to step 5 is often larger than the price of adding two layers to a through hole board.
On a through hole via, any barrel below the layer where the signal exits is a stub. At multi gigabit speeds the stub resonates and eats signal margin. Blind vias remove the stub by design. Back drilling is the cheaper alternative: the fabricator drills out the unused barrel from the bottom, leaving a short residual stub.
Whichever you choose, a via is part of the transmission line. Keep reference plane transitions close with stitching vias nearby, and include the via in your controlled impedance budget, especially on 85 to 100 ohm differential pairs.
Use them when at least one of these is true: a BGA pitch of 0.5 mm or less cannot escape with dog bone fanout; the board outline is fixed and through hole vias would force more layers; or high speed links above roughly 10 Gbps cannot tolerate via stubs and back drilling is not enough. If none apply, stay with through hole vias. Often the cheaper fix is a different package, a better pin assignment, or a component with a larger pitch, which is a part selection decision as much as a layout one.
Via strategy starts with component choices. A 0.4 mm pitch BGA can force an HDI stackup on a board that would otherwise be a simple 6 layer design. An AI assisted flow can flag package pitch, pin count and available alternates during component selection, before the stackup is locked, and check that the via spans in the layout match the stackup and fab notes. Engineers still decide the stackup, but they decide it with the cost of each via type in view. Add these checks to your PCB design review checklist.
A blind via connects an outer layer to an inner layer and is visible on one surface. A buried via connects inner layers only and is not visible from either surface. Both avoid drilling through the full board, but they are made at different steps of lamination.
Yes, compared with through hole vias. Each extra drilling and lamination cycle adds cost and lead time. Single level blind microvias are the cheapest step up; buried vias combined with multiple microvia levels cost the most.
A microvia is a small laser drilled via, usually 0.15 mm or less in diameter, that spans one dielectric layer. Microvias are the basis of HDI PCB design and can be staggered or stacked to reach deeper layers.
Yes. A blind microvia placed in a BGA pad, then filled and plated over, is a common way to escape 0.5 mm and finer pitch BGAs. Filling prevents solder from wicking into the via during assembly.
Use back drilling when a through hole board is otherwise fine but a few high speed nets suffer from via stubs. It removes most of the stub at lower cost than adding a blind via structure across the whole design.
Want to know earlier whether a part will push your board into HDI? Start Your Design with IntelCAD for AI assisted PCB design and component selection.
Image alt-text ideas:
Design your next board by describing it.
Start Your Design
Gerber files for PCB explained: which layers to export, RS-274X vs X2, file extensions, drill files, a fab package checklist and how to check files first.

Short answer: PCB copper thickness is usually specified as copper weight in ounces per square foot. 1 oz copper is about 1.37 mil (roughly 35 µm) thick, 0.5 oz is about half that, and 2 oz is about 2.74 mil (roughly 70 µm). Most boards use 1 oz finished copper on outer layers and 0.5 …

Short answer: Clearance is the shortest distance between two conductors through air. Creepage is the shortest distance between them along the surface of the insulating material. On a PCB, clearance protects against arcing from voltage peaks and transients, while creepage protects against tracking, the slow build-up of conductive paths across a contaminated board surface. Both …